#[non_exhaustive]pub enum LineVoltageForm {
PositiveSequence,
FirstPhase,
}Expand description
Which phasors VoltageSource::calc_line_to_line_voltage reads a
source’s line to line base from.
Variants (Non-exhaustive)§
This enum is marked as non-exhaustive
PositiveSequence
The balanced equivalent of every phasor: √3 |V₁| for three phases
(calc_sequence_components, Fortescue), the phasor difference
|Va − Vb| for two (a split phase pair), the phasor’s magnitude for
one (a single phase source’s own voltage). The multiconductor to
balanced lowering reads it.
FirstPhase
The first phase’s magnitude times the chord of the n phase polygon
(calc_polygon_chord), and for one phase the line to line
equivalent √3 |V| of its magnitude, which is line to neutral
(crate::electrical::calc_wye_line_voltage): the form an MG-RAVENS
or CIM EnergySource, which states one magnitude for a balanced set,
takes its nominalVoltage in. The MG-RAVENS writer reads it.