Skip to main content

calc_terminal_role

Function calc_terminal_role 

Source
pub fn calc_terminal_role<S: AsRef<str>>(
    terminals: &[S],
    terminal: &str,
    conventions: Option<&Value>,
) -> TerminalRole
Expand description

The role of terminal among a bus’s terminals. With BMOPF terminal conventions (the terminal_conventions block, whose neutral and earth lists name terminals) a named terminal takes the role it is named in and every other terminal is a phase. Without conventions n or N is neutral, and so is 4 when the terminals are exactly 1 to 4 (the four wire spelling OpenDSS and PowerModelsDistribution share), and every other terminal is a phase. Ground terminal 0 is earth either way.

The one terminal classification: DistBus::phase_indices, DistBus::neutral_indices, the WYE neutral of a connection (crate::calc_wye_neutral_position), the BMOPF reader, validator and writer, the PMD MATHEMATICAL writer, the multiconductor to balanced lowering, and the CIM and MG-RAVENS readers and writers (over the CIM wire convention, which those readers state for their networks: MulticonductorNetwork::terminal_conventions) read it.