Format fidelity and validation

How powerio’s readers and writers are validated, the conventions they follow, and the known limits. The headline fidelity table is in the top level README; this document covers the conventions and the proof behind it.

Conventions

powerio’s numeric conventions match MATPOWER and PowerModels.jl. The reference implementations and the matching powerio code:

QuantityConventionReferencepowerio
Bus type codes\(1 = \mathrm{PQ}\), \(2 = \mathrm{PV}\), \(3 = \mathrm{ref}\), \(4 = \mathrm{isolated}\)MATPOWER idx_busnetwork::BusType
Impedance, susceptanceper unit on baseMVA, never rescaledMATPOWER idx_brch (BR_B already per unit)format::matpower
Branch terminal admittanceMATPOWER BR_B splits half to each end; richer sources use canonical g_fr/b_fr/g_to/b_to; one-value targets receive the total susceptance projectionPowerModels matpower.jl; MATPOWER idx_brchnetwork::BranchCharging, Branch::terminal_charging
Tap ratio0 means a line (treated as 1); nonzero is a transformerMATPOWER idx_brch TAPBranch::effective_tap
Phase shift, angledegrees in the model; PowerModels JSON carries radiansPowerModels make_per_unit!format::powermodels
Angle limitsangmin/angmax default ±360 (unconstrained)MATPOWER idx_brch ANGMIN/ANGMAXBranch::has_angle_limits
pandapower/PyPSA impedanceline r/x are converted between per unit and ohms with \(Z_{\mathrm{base}} = V_{\mathrm{kV}}^2 / \mathrm{baseMVA}\); pandapower line charging is capacitance per km (c_nf_per_km, converted via \(2\pi f \ell Z_{\mathrm{base}}\)); PyPSA line b is siemenspandapower PPC conversion, PyPSA static componentsformat::pandapower, format::pypsa
dcline Pt/Qf/Qtsign flips vs MATPOWERPowerModels matpower.jlformat::powermodels
Generator cost\(c_2 p^2 + c_1 p\) maps to \(q = 2c_2\), \(c = c_1\); coefficients high order firstMATPOWER idx_cost, egret matpower_parserGenCost::quadratic
source_id["bus", id] for bus-tied elementsPowerModels matpower.jlformat::powermodels
PSLF shuntsEPC pu_mw/pu_mvar are per unit on sbase; Network::Shunt stores MW/MVAr at \(V = 1\)paired EPC/RAW case checksformat::pslf
GO Challenge 3 time seriesNetwork stores the first interval as a static case; .pio.json packages carry replayable later intervals in operating_pointsRust GOC3 package testsformat::goc3, powerio_pkg::operating
Surge anglesSurge JSON carries voltage angles, phase shifts, and angle limits in radians; Network stores degreesRust Surge round trip testsformat::surge

egret’s own MATPOWER parser uses the same reductions (bus type as matpower_bustype, polynomial coefficients reversed to a {degree: coefficient} map, piecewise to [[mw, cost], ...], impedances left per unit), which is why a MATPOWER case taken through powerio to egret JSON matches egret’s direct import.

Validation

The harness script benchmarks/run_validation.sh checks powerio against five independent tools. Every classic text reader and writer runs under an oracle: the conversion matrix covers MATPOWER, PSS/E, and egret sources against all five legacy text targets, every PowerWorld output is read back and bridged to PowerModels JSON, and the PMread leg covers the PowerModels JSON read side. pandapower JSON and PyPSA CSV folders have dedicated import validators because pandapower has its own JSON schema and PyPSA is a directory format; both validate the write direction only — the pandapower JSON and PyPSA readers have no external oracle. They, GO Challenge 3 JSON, Surge JSON, and the remaining source/target pairs (PowerModels JSON and PowerWorld sources into the non-PowerModels targets) rest on the Rust round trip suite.

  • PowerModels.jl (validate_powermodels.jl, validate_psse.jl, core_json.jl). Reads MATPOWER, PowerModels JSON, and PSS/E. The MATPOWER to PowerModels JSON path is checked field by field after per unit normalization; the others by element counts and demand/generation/shunt totals.
  • egret (validate_egret.py). The oracle for egret output, which PowerModels cannot read: it loads powerio’s egret JSON with egret.data.model_data.ModelData and compares counts, totals, and generator cost curves.
  • ExaPowerIO.jl (validate_exapowerio.jl). Reads MATPOWER through powerio’s C ABI and compares value for value.
  • pandapower (validate_pandapower.py, validate_pandapower_converter.py). Cross-checks MATPOWER parse/\(Y_{\mathrm{bus}}\) and imports powerio’s pandapower JSON output back into pandapower, comparing counts and \(Y_{\mathrm{bus}}\).
  • PyPSA (validate_pypsa.py). Imports powerio’s PyPSA CSV folder output and checks counts, totals, line r/x/b rebased from ohms on the bus0 voltage, and transformer r/x/tap_ratio/s_nom rebased from the transformer s_nom base; a line/transformer split mismatch fails the case.

The conversion matrix

benchmarks/validate_matrix.py converts each source to every legacy text target and checks the electrical core of the output (bus/branch/generator counts and the per unit demand, generation, and shunt totals) against the source’s own core, read by an independent oracle. The diagonal is checked byte exact: writing back to the source format reproduces the file. Sources use the real native files where they exist (the vendored PSS/E .raw and egret .json) and representative MATPOWER cases otherwise: basic (case9), shunts and transformers (case14, case30), size (case118, case2869pegase), HVDC with a mixed piecewise/polynomial gencost (t_case9_dcline), and a piecewise-cost case (pglib_opf_case5_pjm).

All 65 legacy text cells pass (13 source cases × 5 targets). The core is preserved by every writer regardless of fidelity tier, so it is the invariant checked across the whole matrix; cost, HVDC, and angle limits are tier specific and covered by the dedicated checks above and the Rust suite. The pandapower JSON and PyPSA CSV validators run alongside this matrix and are reported as separate legs.

Running it

cargo build --release -p powerio-capi
python3.12 -m venv .venv
.venv/bin/python -m pip install --upgrade pip maturin -r benchmarks/requirements.txt
env VIRTUAL_ENV=$PWD/.venv .venv/bin/maturin develop --release
julia --project=benchmarks -e 'using Pkg; Pkg.instantiate()'
bash benchmarks/run_validation.sh

The oracle tools (PowerModels.jl, egret, ExaPowerIO.jl, pandapower, PyPSA) are benchmark scoped: they are declared in benchmarks/Project.toml and benchmarks/requirements.txt, never as dependencies of the powerio package. benchmarks/run_validation.sh requires the Python oracles to import in the selected Python 3.11+ environment; a missing PyPSA, pandapower, or egret import is a setup failure.

Known limits

Write side losses are reported in Conversion::warnings; the pandapower and PyPSA readers itemize what they ignore in Parsed::warnings (read_warnings in Python), naming the table and counting the affected rows. convert_file/convert_str fold the read warnings into Conversion::warnings.

  • PSS/E reads revisions 33, 34, and 35. 3-winding transformers are kept as typed records and star-lowered into \(Y_{\mathrm{bus}}\)/connectivity by the indexed view; two-terminal DC lines map to the neutral HVDC model. A switched shunt keeps its steady-state susceptance BINIT as the shunt b and carries its mode, voltage band, regulated bus, and step blocks. A 2-winding transformer’s magnetizing susceptance round-trips through MAG2 (\(\mathrm{CM} = 1\)). Impedances are assumed on the system base (\(\mathrm{CZ} = \mathrm{CW} = 1\)).
  • PowerWorld .aux is read and written. .pwb binary cases are read only, and .pwd display files parse through the separate display API. .aux carries no system base, so the reader defaults to 100 MVA. No third-party .aux reader exists, so that writer is validated by powerio’s own read back plus a PowerModels JSON bridge. The .pwb layouts are reverse engineered; the decode evidence and coverage matrix are maintainer notes at powerio/src/format/powerworld/FORMAT.md.
  • PSLF .epc is read and written. The reader maps the static power flow core: buses, lines, two- and three-winding transformers, generators, loads, fixed shunts, controlled shunts at initial g/b, and limited two-terminal DC records. Three-winding transformers are kept as typed records and star-lowered into \(Y_{\mathrm{bus}}\)/connectivity by the indexed view. Unsupported sections stay in the retained source text and emit warnings.
  • MATPOWER canonical output (for a case that did not originate as MATPOWER) omits dcline; the byte exact echo path keeps it when the case was read from MATPOWER. Storage is written as an mpc.storage block.
  • egret output drops HVDC and storage. The reader takes the power flow ModelData subset (numeric bus ids, scalar values); unit commitment cases (system.time_keys) are rejected.
  • pandapower JSON writes the power flow core as split oriented pandapowerNet tables. Line ohms are referred to the from bus voltage, as pandapower’s build_branch reads them; a bus with baseKV 0 writes vn_kv set to \(1\) (warned) so the per unit impedances survive. A branch with a tap, a shift, or terminals on two voltage levels becomes a trafo row with tap_changer_type = "Ratio"; its MATPOWER charging b rides as one bus shunt per terminal (warned, \(Y_{\mathrm{bus}}\) exact) because pandapower’s magnetizing model is inductive only. The file is labeled with f_hz set to \(50\) and c_nf_per_km compensated, so a 60 Hz source keeps its exact \(Y_{\mathrm{bus}}\). Reference buses without a generator get an ext_grid row, which reads back as a Ref generator. The writer also warns on dropped HVDC, storage, capability columns, angle limits, rate B/C, non-finite values (written as JSON null), and costs poly_cost cannot carry. The reader models ratio, ideal, and pandapower 2.x tap changers, off-nominal vn_hv_kv/vn_lv_kv, lv side taps, and shunt vn_kv scaling; ZIP load composition, line shunt conductance, magnetizing branches, tabular tap changers, reactive cost coefficients, and every other non-empty table warn with row counts.
  • PyPSA CSV folders are canonicalized directory outputs, not byte exact text conversions. Covered: static buses, generators, loads, lines (ohms on the bus0 voltage, as PyPSA computes them), transformers (rebased between the system base and the transformer s_nom), shunts, storage units, and base MVA. The reader maps links to HVDC with a warning, requires v_nom and balanced CSV quoting, and warns on stores, nonzero g, and every CSV it does not read (time series, carriers). The writer keys tables by bus name, falling back to the numeric id when names collide (warned), and warns on dropped HVDC, q limits, mbase, transformer angle limits, rate B/C, isolated buses, non-finite p limits, and slackless or normalized networks. Nonnumeric bus names read back as dense synthetic ids with the originals on Bus.name.
  • GO Challenge 3 JSON reads ARPA-E GO Competition Challenge 3 input data into the balanced transmission model. Network is static, so the reader maps the first time interval into generator/load bounds and status fields, keeps the original JSON for byte exact source echo, and warns about scheduling data left in the retained source. There is no canonical GOC3 writer from an arbitrary Network; TargetFormat::Goc3Json only succeeds as a same format source echo. When a GOC3 Network is wrapped in .pio.json, powerio-pkg extracts the full input time axis into operating_points. Materializing one point applies those updates to the static payload and clears the series.
  • Surge JSON reads and writes the versioned surge-json network document. The reader maps buses, loads, fixed shunts, branches, generators, storage, and HVDC links into Network, retains the original source for same format echo, and warns about source sections that stay only in the retained document. The writer emits a canonical Surge network body for the supported power flow core; richer MATPOWER generator capability or ramp columns and unsupported cost shapes are reported in Conversion::warnings.
  • gridfm (read, the gridfm feature in powerio-matrix) reconstructs a Network from the gridfm-datakit Parquet dataset: lossy, but it recovers everything a power flow needs. That is bus types/voltages/limits, nodal load and shunt totals, generator dispatch and bounds, branch r/x/b/tap/shift/rate_a/angle limits, and baseMVA; it can’t recover original bus ids (synthesized 1..n), per element load/shunt granularity (folded one synthetic element per bus), piecewise/cubic gen costs (read as none), or HVDC/storage. Because the writer stores the effective tap, a branch with unit tap and no phase shift is read back as a line (raw \(\mathrm{tap} = 0\)); a unity ratio, zero shift transformer in the source is thus read as a line (the power flow is identical). The losses are returned as a warnings list on GridfmRead, mirroring Conversion::warnings. The same direction writer is documented in the top level README.

Missing generator costs

PSS/E .raw files carry no generator cost curves. Converting a PSS/E case to MATPOWER writes mpc.gen and omits mpc.gencost with a warning; powerio does not invent zero costs. A workflow that needs costs must pick an explicit policy:

powerio convert case.raw --from psse --to matpower --missing-gen-cost zero -o case.m
powerio dcopf case.m -o out --missing-gen-cost quadratic --default-gen-cost 0.01,2.0,0.0
powerio gridfm case.raw --from psse -o out --missing-gen-cost zero
  • preserve: leave missing costs absent (default for conversion and GridFM export);
  • require: fail on an in-service generator without cost (default for DC OPF export);
  • zero: fill missing rows with a MATPOWER polynomial cost [0, 0, 0];
  • quadratic: fill missing rows with --default-gen-cost C2,C1,C0.

--gen-cost-csv overrides costs by generator row before the missing-cost policy runs. The header is gen_index,bus,c2,c1,c0,startup,shutdown: gen_index is zero based in the current generator table, bus must match that generator’s bus id (catching stale tables after reordering), and startup/shutdown default to zero. GridFM stores cp0/cp1/cp2 columns; missing or unsupported costs still write zero columns, and the manifest separates missing_cost_gens, unsupported_cost_gens, zeroed_cost_gens, and synthesized_gen_costs.