Core concepts

PowerIO borrows its structure from compiler infrastructure. Source text and the data a program computes with are different representations, and you move between them through a small set of explicit, checked operations. The electrical content is described in ordinary power system terms, and the same types and operations appear in Rust, C, Python, Julia, PowerIO IR, and the MCP server.

The module

PioModule<T> contains one typed value and the data that explains it:

PioModule<T>
├── value: T
├── diagnostics
├── producer
├── sources and source map
├── history
└── extensions

In Rust you reach the value through module.value() and the diagnostics through module.diagnostics(). Python and Julia expose both as properties, value and diagnostics, and C exposes borrowed accessors because its values are opaque. Diagnostics belong to the module rather than to the network or solution inside it.

While the process runs, a module can keep the bytes it was parsed from, which is how writing it back to its own format reproduces them byte for byte. Those bytes are not part of serialized PowerIO IR, and editing the value drops them, so the next same format write serializes the edited value instead of the old bytes.

Values

PioValue is the closed set of types a module can contain at the dynamic boundary, meaning automatic parsing, PowerIO IR, the C, Python, and Julia bindings, and the MCP server.

BalancedNetwork
MulticonductorNetwork
OperatingPoint<BalancedNetwork>
OperatingPoint<MulticonductorNetwork>
TimeSeries<T>
ScenarioSet<T>
DcPfInstance, AcPfInstance, DcOpfInstance, AcOpfInstance,
McAcPfInstance, McAcOpfInstance, LinDist3FlowOpfInstance, AcScucInstance
DcPfSolution, AcPfSolution, DcOpfSolution, AcOpfSolution, SocwrOpfSolution,
McAcPfSolution, McAcOpfSolution, LinDist3FlowOpfSolution, AcScucSolution
GeoLayer
TypeMeaning
BalancedNetworkA self contained balanced case: equipment identities, terminals, physical parameters, ratings, limits, costs, and the source’s operating assignment.
MulticonductorNetworkThe conductor resolved distribution model.
OperatingPoint<N>A possibly partial alternate electrical assignment over fixed equipment. It makes no claim of completeness or power flow feasibility.
TimeSeries<T>Values of one type ordered in time.
ScenarioSet<T>Named alternatives of one type, optionally with probabilities and with no time order.
*InstanceThe complete input of one named calculation: fixed inputs, unknowns, bounds, objectives, horizon, contingencies, and formulation choices.
*SolutionThe result of one calculation: computed quantities, termination, residuals, multipliers, and the objective or bound.
GeoLayerCoordinates and routes for the elements of a case, as a document of its own.

The two network types are peers, and neither is a subtype of the other. BalancedNetwork is where MATPOWER, PSS/E, XIIDM, CGMES, and the other balanced formats meet; MulticonductorNetwork is where OpenDSS, PowerModelsDistribution JSON, and BMOPF meet. To get a balanced positive sequence equivalent from a multiconductor network you call an explicit transformation, which reports each assumption it made and each thing it lost.

A BalancedNetwork parsed from PSS/E and one parsed from MATPOWER are the same type with the same meanings. Each format has a documented profile, and data outside that profile is reported and stays in the retained source; it is not folded into the model. There is no universal network format. The balanced model does not absorb multiconductor data, other energy carriers, or calculation data.

A Rust application can put its own type in a module, PioModule<MyType>, and get the same source, diagnostic, and history behavior. That type stays outside the dynamic boundary until PowerIO adds it to PioValue, the IR schema, and the bindings, so until then it cannot pass through PowerIO IR or reach the other languages.

Operating points

An operating point can override demand, setpoints, dispatch, voltages, injections, equipment service status, switch positions, transformer taps, phase shifts, and the corresponding multiconductor controls. Any quantity it leaves out resolves to the network’s own assignment, which is why an operating point can be partial.

It cannot change equipment identities or terminals, physical parameters, ratings, costs, commitment or reserve structure, the horizon, or the equipment set. If your scenario changes any of those, it contains a network or a calculation instance instead of an operating point.

Topology is calculated from the declared terminals, equipment service status, and switch positions, which together give the energized connectivity. Tap and phase shift changes affect the equations and leave the connectivity alone.

Collections

TimeSeries<T> and ScenarioSet<T> nest without flattened names, so TimeSeries<OperatingPoint<BalancedNetwork>>, ScenarioSet<TimeSeries<BalancedNetwork>>, and the other combinations keep their structural type. An operating point entry refers to the shared base network instead of copying its tables, so a series of operating points contains one network and one sparse set of overrides per point. A series of networks or instances contains complete values when their physical or calculation data differs.

Indexing a collection returns the contained value or a view rooted in the owning module; nothing reparses and no complete network is copied.

Calculation instances and solutions

Network data, calculation inputs, and results are separate types. A MATPOWER case parses to a BalancedNetwork, and you construct a DcPfInstance, AcPfInstance, DcOpfInstance, or AcOpfInstance from it. A solver takes the instance and returns the corresponding solution; PowerIO itself never solves.

SocwrOpfSolution is a PowerModels SOCWR relaxation together with its objective lower bound. It is not an AcOpfSolution unless voltage recovery and AC residual checks support that claim.

Diagnostics

Every operation reports diagnostics. Each Diagnostic has a stable dotted code, a severity (error, warning, remark, or note), a message, and, where available, a target, source byte spans, related diagnostics, and a suggested action. Branch on the code rather than on the rendered message; the code is the part that stays stable.

A successful operation keeps its diagnostics on the returned module or result. A failed operation returns or raises the language’s PowerIO error, which contains the same diagnostics.

Sources, formats, and destinations

A Source owns one or more named immutable byte buffers read from a file, a directory, or memory. In Rust and C you build it yourself, since those languages need an explicit owner for the bytes. Python and Julia take a path, an open file, or a bytes value directly, because the interpreter already owns them; Rust, Python, Julia, and C explains the split. parse detects the format from the source name and content unless you declare one.

emit writes one format and returns an EmitResult. The result contains one artifact per file produced, each with its name and either its bytes (for a memory destination) or its path after a write; the layout, which is one file or a directory; the fidelity, which is either an exact echo of retained source bytes or fresh canonical output; and the emission diagnostics, which report each loss. A single file format produces one artifact, and a directory format such as PyPSA CSV, GridFM, or CGMES produces one per file.

resolve_format maps an accepted spelling of a format to its canonical token and reports the conventional file suffix, the output layout, and whether a fresh writer exists. It describes formats only; values are named by PioValue and its counterparts in each language.

PowerIO IR

serialize writes a module as PowerIO IR and deserialize reads it back with its types, diagnostics, sources, history, and extensions intact. The document has an integer version that changes only when an existing serialized representation changes incompatibly. Additive structural types keep the same IR version and require a reader implementing those types. PowerIO IR is absent from grid exchange format discovery, so parse does not accept it. PowerIO IR defines the document and its version rule.

Derived data

Sparse matrices, dense solver rows, factorizations, and caches are analysis data computed from a value. They keep element mappings back into that value, they are not stored in a module, and their representation can change without changing any public meaning.

Every transformation declares its input and output types and returns diagnostics. Multiconductor to balanced conversion moves to a less detailed representation under stated assumptions, while constructing an instance from a network moves to a more specific one. Format conversion is parse followed by emit at the same level. LLVM and MLIR lessons lists the decisions PowerIO shares with LLVM and MLIR and the ones it does not.